25 GHz pulse level radar fill level
transmitter in two-wire technology for the continuous
monitoring of liquids and slurries in storage and process
tanks, even at high temperatures and pressure. Antenna-
dependent. Ideal for small tanks Process Connection and
Antenna Material: 316L (1.4435 or 1.4404) stainless steel,
PTFE emitter, FKM seal Process Connection Type: Threaded
connections 316L: 2" NPT (Taper) (ASME B1.20.1) (tapered
thread) Communication: 4-20mA HART, start-up at <3.6mA .
Enclosure (with Cable Inlets): Aluminum, Epoxy paint, 2 x
M20 x 1.5 Antenna Version, Size/Extension: Antenna
/Extension 316L: 2 inch Horn (fits 2 inch ASME or DN 50
nozzles) Approvals: Intrinsically Safe: IECEx/ATEX II 1 G Ex
INMETRO Ex ia IIC T4 Ga, Ex ia ta IIIC T100 C Da, CE,
RED, RCM Pressure Rating: Rating per
pressure/temperature curves in instruction manual